Device: /dev/sdb [USB Prolific], 7 Currently unreadable (pending) sectors
Current_Pending_Sector
現在異常があり、代替処理を待つセクタの総数。もし後で読み込みに成功したセクタがあれば、この値は減少する。
確認
[root@falcon21 ~]# smartctl -a /dev/sdb smartctl 6.5 2016-05-07 r4318 [x86_64-linux-3.10.0-862.3.2.el7.x86_64.debug] (local build) Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Western Digital Caviar SE Serial ATA Device Model: WDC WD2500JS-22NCB1 Serial Number: WD-WCANKH293486 Firmware Version: 10.02E02 User Capacity: 250,058,268,160 bytes [250 GB] Sector Size: 512 bytes logical/physical Device is: In smartctl database [for details use: -P show] ATA Version is: ATA/ATAPI-7 (minor revision not indicated) Local Time is: Fri May 3 20:14:08 2019 JST SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED See vendor-specific Attribute list for marginal Attributes. General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 7680) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 90) minutes. Conveyance self-test routine recommended polling time: ( 6) minutes. SCT capabilities: (0x103f) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. スマート総合健康自己評価テスト結果:PASSED 限界属性については、ベンダー固有の属性リストを参照してください。 一般的なSMART値: オフラインデータ収集ステータス:(0x82)オフラインデータ収集アクティビティ ????????????????????????????????????????エラーなしで完了しました。 ????????????????????????????????????????自動オフラインデータ収集:有効 セルフテストの実行状態:(0)前回のセルフテストルーチンが完了しました ????????????????????????????????????????エラーなしで、またはセルフテストはこれまでにありません。 ????????????????????????????????????????実行されました。 オフライン完了までの合計時間 データ収集:(7680)秒。 オフラインデータ収集 capabilities:(0x7b)SMARTはすぐにオフラインで実行します。 ????????????????????????????????????????自動オフラインデータ収集のオン/オフサポート。 ????????????????????????????????????????オフラインでの収集を新規に中止する ????????????????????????????????????????コマンド。 ????????????????????????????????????????オフラインサーフェススキャンがサポートされています。 ????????????????????????????????????????セルフテスト対応 ????????????????????????????????????????搬送セルフテスト対応 ????????????????????????????????????????選択的セルフテストがサポートされています。 SMART機能:(0x0003)入る前にSMARTデータを保存します ????????????????????????????????????????省電力モード。 ????????????????????????????????????????SMART自動保存タイマーをサポートします。 エラーロギング機能:(0x01)エラーロギングがサポートされています。 ????????????????????????????????????????汎用ロギングがサポートされています。 短いセルフテストルーチン 推奨ポーリング時間:(2)分 拡張自己診断ルーチン 推奨ポーリング時間:(90)分 搬送セルフテストルーチン 推奨ポーリング時間:(6)分 SCT機能:(0x103f)SCTステータスがサポートされています。 ????????????????????????????????????????SCTエラー回復制御がサポートされています。 ????????????????????????????????????????SCT機能制御がサポートされています。 ????????????????????????????????????????SCTデータテーブルがサポートされています。 SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: SMART属性データ構造改訂番号:16 しきい値を持つベンダー固有のSMART属性: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 200 200 051 Pre-fail Always - 0 3 Spin_Up_Time 0x0003 199 171 021 Pre-fail Always - 5041 4 Start_Stop_Count 0x0032 094 094 000 Old_age Always - 6246 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0 7 Seek_Error_Rate 0x000f 200 200 051 Pre-fail Always - 0 9 Power_On_Hours 0x0032 086 086 000 Old_age Always - 10659 10 Spin_Retry_Count 0x0013 100 100 051 Pre-fail Always - 0 11 Calibration_Retry_Count 0x0012 100 100 051 Old_age Always - 0 12 Power_Cycle_Count 0x0032 094 094 000 Old_age Always - 6099 190 Airflow_Temperature_Cel 0x0022 048 031 045 Old_age Always In_the_past 52 194 Temperature_Celsius 0x0022 098 081 000 Old_age Always - 52 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0 197 Current_Pending_Sector 0x0012 200 200 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0010 200 200 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 8 200 Multi_Zone_Error_Rate 0x0009 200 200 051 Pre-fail Offline - 0 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS SMARTセルフテストログ構造のリビジョン番号1 セルフテストは記録されていません。 [セルフテストを実行するには、:smartctl -tを使用してください。 SMART選択的セルフテストログデータ構造の改訂番号1 ? SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. 選択的セルフテストフラグ(0x0): 選択したスパンをスキャンした後、ディスクの残りの部分を読み取りスキャンしないでください。 選択的セルフテストが電源投入時に保留中の場合は、0分後に再開します。 セルフテストを実行し、不良個所を確認 [root@falcon21 ~]# smartctl -t long /dev/sdb smartctl 6.5 2016-05-07 r4318 [x86_64-linux-3.10.0-862.3.2.el7.x86_64.debug] (local build) Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org === START OF OFFLINE IMMEDIATE AND SELF-TEST SECTION === Sending command: "Execute SMART Extended self-test routine immediately in off-line mode". Drive command "Execute SMART Extended self-test routine immediately in off-line mode" successful. Testing has begun. Please wait 90 minutes for test to complete. Test will complete after Fri May 3 21:59:34 2019 Use smartctl -X to abort test. ===オフラインでの自己診断と自己診断セクションの開始=== コマンド送信:「オフラインモードでSMART Extendedセルフテストルーチンを直ちに実行する」。 ドライブコマンド "SMART Extendedセルフテストルーチンをオフラインモードですぐに実行する"が成功しました。 テストが始まりました。 テストが完了するまで90分お待ちください。 テストは金5月3日21:59:34 2019以降に完了します テストを中止するには、smartctl -Xを使用してください。 ---------------------------------- 修復を確認 「Current_Pending_Sector」と「Offline_Uncorrectable」の値が「0」になっていることを確認。 [root@falcon21 ~]# smartctl -a /dev/sdb [root@falcon21 ~]# smartctl -a /dev/sdb smartctl 6.5 2016-05-07 r4318 [x86_64-linux-3.10.0-862.3.2.el7.x86_64.debug] (local build) Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Western Digital Caviar SE Serial ATA Device Model: WDC WD2500JS-22NCB1 Serial Number: WD-WCANKH293486 Firmware Version: 10.02E02 User Capacity: 250,058,268,160 bytes [250 GB] Sector Size: 512 bytes logical/physical Device is: In smartctl database [for details use: -P show] ATA Version is: ATA/ATAPI-7 (minor revision not indicated) Local Time is: Sat May 4 07:00:36 2019 JST SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED See vendor-specific Attribute list for marginal Attributes. General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 7680) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 90) minutes. Conveyance self-test routine recommended polling time: ( 6) minutes. SCT capabilities: (0x103f) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 200 200 051 Pre-fail Always - 0 3 Spin_Up_Time 0x0003 199 171 021 Pre-fail Always - 5041 4 Start_Stop_Count 0x0032 094 094 000 Old_age Always - 6246 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0 7 Seek_Error_Rate 0x000f 200 200 051 Pre-fail Always - 0 9 Power_On_Hours 0x0032 086 086 000 Old_age Always - 10670 10 Spin_Retry_Count 0x0013 100 100 051 Pre-fail Always - 0 11 Calibration_Retry_Count 0x0012 100 100 051 Old_age Always - 0 12 Power_Cycle_Count 0x0032 094 094 000 Old_age Always - 6099 190 Airflow_Temperature_Cel 0x0022 052 031 045 Old_age Always In_the_past 48 194 Temperature_Celsius 0x0022 102 081 000 Old_age Always - 48 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0 197 Current_Pending_Sector 0x0012 200 200 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0010 200 200 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 8 200 Multi_Zone_Error_Rate 0x0009 200 200 051 Pre-fail Offline - 0 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Extended offline Completed without error 00% 10661 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. |
投票数:1
平均点:10.00